Table 3

Summery of Commands

BBRC Command
Number
MnemonicBBRC Bilevel
Number
BilevelStateRemarks
R 4330

4331

HV1 pwr on

off

71-21HV1 pwr1

0

Turns on/off high voltage supply1, change can also be noted on HVMON. Transmit R4330 only when +28 bus is on.
4332

4333

HV1 msb hi

lo

71-22HV1 msb1

0

Selects programming resistors which control the output of HV supply 1.
4334

4335

HV1 lsb hi

lo

71-23HV1 lsb1

0

Change can also be noted on HVMON.
4336

4337

DISCR 1 hi

lo

71-24DISCR 11

0

Selects level of PPA 1's pulse amplitude discriminator.
4338

4339

DSS 1 A

B

71-25DSS 10

1

Selects channel A/B as data source for PPA 1.
R4350

4351

HV2 pwr on

off

71-26HV2 pwr1

0

Turns on/off high voltage supply 2, change can also be noted on HVMON. Transmit R4350 only when +28 bus is on.
4352

4353

HV2 msb hi

lo

71-27HV MSB1Selects programming resistors which control the output of HV supply 2.
4354

4355

HV2 lsb hi

lo

71-28HV1 lsb1Change can also be noted on HVMON.
4356

4357

DISCR 2 hi

lo

71-29DISCR 21

0

Selects level of PPA 2's pulse amplitude discriminator.
4358

4359

DSS 2 A

B

71-30DSS 20

1

Selects channel A/B as data source for PPA 2.
R4370

R4371

LVS A

B

71-31LVS0

1

Selects primary/backup low voltage power supply for experiment electronics. Transmit only when +28V bus is off.
4313


4312

RESOL 10 A

5 A

71-32RESOL0


1

Selects 5/10 Angstrom resolution mode of the memory.
4314


4315

HRES PPA 1

PPA 2

71-33HRES PPA1


0

Selects PPA 1/2 as data sources when memory is in 5 angstrom resolution mode. Also selects PPA 1/2 as data source when ECOM is in SERIAL data mode.
R4310


4311

PHOTOM on

off

71-34PHOTOM1


0

Turns on/off the photometer.
In addition, the following five commands have no bilevel monitors
4318GRATING STEP------Connects +28V bus 2 to a Ledex 36-step continuous rotation stepping motor. T/M verification is by noting a change in the GRATING analog monitor.
4302


4303

MEMORY DATA

SERIAL DATA

------SCF Mode 30


SCF Mode 31 Selects source of 8-bit digital data to be either the TRW add-one memory, or the output of a PPA directly (as selected by the HRES PPA relay). Instead of a bilevel, the MEMORY/SERIAL flag to software is the state of the DSS 2 bilevels, see Table 4. SCF mode refers to the data processing and display mode at the Satellite Control Facility.

4316

4317

DET O'LOAD on

off

------Turns on/off the detector overload automatic shutdown function. If on and if the detector event rate exceeds 10200/sec, then the circuit will automatically turn off HV1 and/or HV2. The HV1 and/or HV2 bilevels will then be 0. After 255 seconds the HV supplies will automatically be turned back on. If this function is off, then there is no effect on the experiments functioning.
This final command is implemented by the spacecraft.
4300


4301

ECOM-721 on

off

71-35Ecom-7211


0

Turns on/off +28V buses 1 and 2.