| BBRC Command Number | Mnemonic | BBRC Bilevel Number | Bilevel | State | Remarks |
| R 4330 4331 | HV1 pwr on | 71-21 | HV1 pwr | 1 0 | Turns on/off high voltage supply1, change can also be noted on HVMON. Transmit R4330 only when +28 bus is on. |
| 4332 4333 | HV1 msb hi lo | 71-22 | HV1 msb | 1 0 | Selects programming resistors which control the output of HV supply 1. |
| 4334 4335 | HV1 lsb hi lo | 71-23 | HV1 lsb | 1 0 | Change can also be noted on HVMON. |
| 4336 4337 | DISCR 1 hi lo | 71-24 | DISCR 1 | 1 0 | Selects level of PPA 1's pulse amplitude discriminator. |
| 4338 4339 | DSS 1 A B | 71-25 | DSS 1 | 0 1 | Selects channel A/B as data source for PPA 1. |
| R4350 4351 | HV2 pwr on off | 71-26 | HV2 pwr | 1 0 | Turns on/off high voltage supply 2, change can also be noted on HVMON. Transmit R4350 only when +28 bus is on. |
| 4352 4353 | HV2 msb hi lo | 71-27 | HV MSB | 1 | Selects programming resistors which control the output of HV supply 2. |
| 4354 4355 | HV2 lsb hi lo | 71-28 | HV1 lsb | 1 | Change can also be noted on HVMON. |
| 4356 4357 | DISCR 2 hi lo | 71-29 | DISCR 2 | 1 0 | Selects level of PPA 2's pulse amplitude discriminator. |
| 4358 4359 | DSS 2 A B | 71-30 | DSS 2 | 0 1 | Selects channel A/B as data source for PPA 2. |
| R4370 R4371 | LVS A B | 71-31 | LVS | 0 1 | Selects primary/backup low voltage power supply for experiment electronics. Transmit only when +28V bus is off. |
| 4313
| RESOL 10 A 5 A | 71-32 | RESOL | 0
| Selects 5/10 Angstrom resolution mode of the memory. |
| 4314
| HRES PPA 1 PPA 2 | 71-33 | HRES PPA | 1
| Selects PPA 1/2 as data sources when memory is in 5 angstrom resolution mode. Also selects PPA 1/2 as data source when ECOM is in SERIAL data mode. |
| R4310
| PHOTOM on off | 71-34 | PHOTOM | 1
| Turns on/off the photometer. |
| In addition, the following five commands have no bilevel monitors | |||||
| 4318 | GRATING STEP | -- | -- | -- | Connects +28V bus 2 to a Ledex 36-step continuous rotation stepping motor. T/M verification is by noting a change in the GRATING analog monitor. |
| 4302
| MEMORY DATA SERIAL DATA | -- | -- | -- | SCF Mode 30
|
| 4316 4317 | DET O'LOAD on off | -- | -- | -- | Turns on/off the detector overload automatic shutdown function. If on and if the detector event rate exceeds 10200/sec, then the circuit will automatically turn off HV1 and/or HV2. The HV1 and/or HV2 bilevels will then be 0. After 255 seconds the HV supplies will automatically be turned back on. If this function is off, then there is no effect on the experiments functioning. |
| This final command is implemented by the spacecraft. | |||||
| 4300
| ECOM-721 on off | 71-35 | Ecom-721 | 1
| Turns on/off +28V buses 1 and 2. |